Process-liquid production
Bag and cartridge housings remove specified suspended particles from compatible liquids between process stages. Media, seals and element efficiency are selected around the liquid, flow and required retention performance.
Sprint Tech Manufacturing Inc.
Industrial filtration products for process liquids, compressed air, hydraulic fluids and lubricants. Select complete housings, strainers and filtration units alongside compatible elements, seals and monitoring accessories for the defined contaminant-removal duty.
Bag and cartridge housings, filter bags and cartridges
Basket strainers, duplex strainers and backwashing filters
Coalescing, particulate, return-line and in-line filters
Explore the category
Bag and cartridge filter housings remove suspended particles from compatible process liquids.
Explore products02 / FILTRATION SYSTEMS
Pipeline strainers capture larger particles before they reach sensitive downstream equipment.
Explore products03 / FILTRATION SYSTEMS
Compressed-air filtration uses different stages to address particles, liquid droplets, aerosols and selected vapours.
Explore products04 / FILTRATION SYSTEMSHydraulic and lubrication filters control particulate contamination in machinery fluid circuits.
Explore productsProduct directory
Explore equipment, consumables, compatible replacement parts and accessories for specification-led supply.
Representative cartridge elements and process-filter equipment.
Details
Bag and cartridge filter housings remove suspended particles from compatible process liquids. Bag systems suit a range of general particle-removal duties, while cartridge choices allow the media type and stated retention performance to be matched more closely to the process. Single-element, multi-element and multi-bag arrangements depend on flow, contamination loading and service intervals. Housing materials, seals and connections must suit the liquid and operating conditions. Replacement enquiries should identify element dimensions, end fittings and the required filtration efficiency. A micron label alone is insufficient: the specified retention basis and test information should be checked for the selected element.
For selection: Liquid and concentration; Flow and contaminant loading; Retention efficiency and test basis; Pressure and temperature; Connection standard; Element size and seal material
Item

Details
Pipeline strainers capture larger particles before they reach sensitive downstream equipment. Basket and duplex arrangements can be selected around the maintenance access and continuity required by the process. Where solids loading or operating patterns justify it, automatic backwashing and mechanically cleaned filters provide alternative ways to remove collected material. Selection depends on particle characteristics, fluid viscosity, available pressure and the acceptable pressure loss. The cleaning method also affects utility requirements and the discharge or collection arrangement. Replacement baskets, screens, seals and cleaning components should match the original model and specified aperture rather than an assumed universal equivalent.
For selection: Flow and fluid viscosity; Solids size and loading; Screen aperture; Permitted pressure drop; Operating pressure and temperature; Cleaning utilities and discharge arrangement
Item

Details
Compressed-air filtration uses different stages to address particles, liquid droplets, aerosols and selected vapours. Water separators remove bulk entrained liquid, coalescing elements capture fine liquid aerosols, and particulate filters retain solid contamination. Activated-carbon stages may be specified for suitable hydrocarbon-vapour removal duties. Each stage must be selected for the required outlet quality and actual operating flow, pressure and temperature. Filters do not replace a dryer where a controlled pressure dew point is required. Supply enquiries can include housings, matched replacement elements, drains and differential-pressure accessories. Claimed air-quality classes require confirmation for the complete selected treatment arrangement.
For selection: Actual air demand and reference conditions; Minimum operating pressure; Temperature; Required air quality; Existing treatment stages; Connection and drain requirements
Item
Details
Hydraulic and lubrication filters control particulate contamination in machinery fluid circuits. Product families include return-line, suction and in-line filters, with spin-on, in-tank and duplex formats available for appropriate duties. Filter location, fluid viscosity and temperature influence the required element and housing arrangement. Selection should also consider the target cleanliness level, element efficiency, bypass arrangement and pressure conditions, rather than nominal micron size alone. Enquiries can cover complete assemblies or replacement elements for existing equipment. Part numbers, housing identification and the fluid specification help establish compatibility; seals, indicators and other service components are matched to the selected filter assembly.
For selection: Hydraulic or lubricant fluid type; Flow and viscosity range; Pressure and temperature; Target cleanliness and efficiency; Bypass requirements; Housing model and element part number
Item
Where products are used
Select filters, strainers and replacement elements for the contaminant, fluid and downstream equipment involved.
Bag and cartridge housings remove specified suspended particles from compatible liquids between process stages. Media, seals and element efficiency are selected around the liquid, flow and required retention performance.
Pipeline strainers capture larger particles before they reach pumps, valves and other downstream equipment. Screen aperture, allowable pressure loss and access for cleaning guide basket, duplex or self-cleaning arrangements.
Separators and particulate or coalescing filters address the specified liquid and particle contamination in compressed air. The complete treatment arrangement must be checked against the required outlet quality and any separate drying duty.
Return-line, suction and pressure-line filters control particulate contamination in hydraulic circuits. The machine's fluid, flow, pressure and target cleanliness determine the housing, bypass arrangement and replacement element.
Lubrication filters retain specified particles in oil circuits serving industrial machinery. Oil viscosity, temperature and the equipment's service arrangement guide element efficiency, housing format and matched indicator components.
Basket strainers or suitable filter housings intercept specified debris as liquids move between storage and process equipment. Contamination loading, transfer flow and the acceptable interruption for cleaning shape the selected arrangement.
Start with your specification
Share your product requirements, quantities and delivery destination to discuss material and equipment supply.
If you don’t find the products you need in our shop, send us your requirements or product list, and we’ll quote you directly.
Sprint Tech Manufacturing Inc.
Industrial filtration products for process liquids, compressed air, hydraulic fluids and lubricants. Select complete housings, strainers and filtration units alongside compatible elements, seals and monitoring accessories for the defined contaminant-removal duty.
Bag and cartridge housings, filter bags and cartridges
Basket strainers, duplex strainers and backwashing filters
Coalescing, particulate, return-line and in-line filters
Explore the category
Bag and cartridge filter housings remove suspended particles from compatible process liquids.
Explore products02 / FILTRATION SYSTEMS
Pipeline strainers capture larger particles before they reach sensitive downstream equipment.
Explore products03 / FILTRATION SYSTEMS
Compressed-air filtration uses different stages to address particles, liquid droplets, aerosols and selected vapours.
Explore products04 / FILTRATION SYSTEMSHydraulic and lubrication filters control particulate contamination in machinery fluid circuits.
Explore productsProduct directory
Explore equipment, consumables, compatible replacement parts and accessories for specification-led supply.
Representative cartridge elements and process-filter equipment.
Details
Bag and cartridge filter housings remove suspended particles from compatible process liquids. Bag systems suit a range of general particle-removal duties, while cartridge choices allow the media type and stated retention performance to be matched more closely to the process. Single-element, multi-element and multi-bag arrangements depend on flow, contamination loading and service intervals. Housing materials, seals and connections must suit the liquid and operating conditions. Replacement enquiries should identify element dimensions, end fittings and the required filtration efficiency. A micron label alone is insufficient: the specified retention basis and test information should be checked for the selected element.
For selection: Liquid and concentration; Flow and contaminant loading; Retention efficiency and test basis; Pressure and temperature; Connection standard; Element size and seal material
Item

Details
Pipeline strainers capture larger particles before they reach sensitive downstream equipment. Basket and duplex arrangements can be selected around the maintenance access and continuity required by the process. Where solids loading or operating patterns justify it, automatic backwashing and mechanically cleaned filters provide alternative ways to remove collected material. Selection depends on particle characteristics, fluid viscosity, available pressure and the acceptable pressure loss. The cleaning method also affects utility requirements and the discharge or collection arrangement. Replacement baskets, screens, seals and cleaning components should match the original model and specified aperture rather than an assumed universal equivalent.
For selection: Flow and fluid viscosity; Solids size and loading; Screen aperture; Permitted pressure drop; Operating pressure and temperature; Cleaning utilities and discharge arrangement
Item

Details
Compressed-air filtration uses different stages to address particles, liquid droplets, aerosols and selected vapours. Water separators remove bulk entrained liquid, coalescing elements capture fine liquid aerosols, and particulate filters retain solid contamination. Activated-carbon stages may be specified for suitable hydrocarbon-vapour removal duties. Each stage must be selected for the required outlet quality and actual operating flow, pressure and temperature. Filters do not replace a dryer where a controlled pressure dew point is required. Supply enquiries can include housings, matched replacement elements, drains and differential-pressure accessories. Claimed air-quality classes require confirmation for the complete selected treatment arrangement.
For selection: Actual air demand and reference conditions; Minimum operating pressure; Temperature; Required air quality; Existing treatment stages; Connection and drain requirements
Item
Details
Hydraulic and lubrication filters control particulate contamination in machinery fluid circuits. Product families include return-line, suction and in-line filters, with spin-on, in-tank and duplex formats available for appropriate duties. Filter location, fluid viscosity and temperature influence the required element and housing arrangement. Selection should also consider the target cleanliness level, element efficiency, bypass arrangement and pressure conditions, rather than nominal micron size alone. Enquiries can cover complete assemblies or replacement elements for existing equipment. Part numbers, housing identification and the fluid specification help establish compatibility; seals, indicators and other service components are matched to the selected filter assembly.
For selection: Hydraulic or lubricant fluid type; Flow and viscosity range; Pressure and temperature; Target cleanliness and efficiency; Bypass requirements; Housing model and element part number
Item
Where products are used
Select filters, strainers and replacement elements for the contaminant, fluid and downstream equipment involved.
Bag and cartridge housings remove specified suspended particles from compatible liquids between process stages. Media, seals and element efficiency are selected around the liquid, flow and required retention performance.
Pipeline strainers capture larger particles before they reach pumps, valves and other downstream equipment. Screen aperture, allowable pressure loss and access for cleaning guide basket, duplex or self-cleaning arrangements.
Separators and particulate or coalescing filters address the specified liquid and particle contamination in compressed air. The complete treatment arrangement must be checked against the required outlet quality and any separate drying duty.
Return-line, suction and pressure-line filters control particulate contamination in hydraulic circuits. The machine's fluid, flow, pressure and target cleanliness determine the housing, bypass arrangement and replacement element.
Lubrication filters retain specified particles in oil circuits serving industrial machinery. Oil viscosity, temperature and the equipment's service arrangement guide element efficiency, housing format and matched indicator components.
Basket strainers or suitable filter housings intercept specified debris as liquids move between storage and process equipment. Contamination loading, transfer flow and the acceptable interruption for cleaning shape the selected arrangement.
Start with your specification
Share your product requirements, quantities and delivery destination to discuss material and equipment supply.
If you don’t find the products you need in our shop, send us your requirements or product list, and we’ll quote you directly.
We use cookies to provide you a better user experience on this website. Cookie Policy